Safonol | IEC/EN 60898-1 | ||||
Pegwn Rhif | 1P,1P+N, 2P, 3P,3P+N,4P | ||||
Foltedd graddedig | AC 230V/400V | ||||
Cyfredol Graddedig(A) | 20A,25A,32A,40A,50A,63A,80A,100A,125A | ||||
Cromlin faglu | C, D | ||||
Capasiti cylched byr graddedig (lcn) | 10000A | ||||
Capasiti cylched byr gwasanaeth graddedig (Ics) | 7500A | ||||
Amledd graddedig | 50/60Hz | ||||
Gall ysgogiad graddedig wrthsefyll foltedd Uimp | 6kV | ||||
Terfynell cysylltiad | Terfynell piler gyda chlamp | ||||
Dygnwch electro-fecanyddol | Ins100=10000:n125=8000 | ||||
Uchder Cysylltiad Terminali | 20mm | ||||
Capasiti cysylltiad | Dargludydd hyblyg 35mm² | ||||
Dargludydd anhyblyg 50mm² | |||||
Gosodiad | Ar reilffordd DIN cymesur 35mm | ||||
Mowntio panel |
Prawf | Math Baglu | Prawf Cyfredol | Cyflwr Cychwynnol | Amserydd baglu Darparwr Amser nad yw'n faglu | |
a | Oedi amser | 1.05Mewn | Oer | t≤1h(In≤63A) t≤2h(ln>63A) | Dim Baglu |
b | Oedi amser | 1.30Mewn | Ar ol prawf a | t<1a(Yn ≤63A) t<2a(Mewn>63A) | Baglu |
c | Oedi amser | 2Mewn | Oer | 10s 20s63A) | Baglu |
d | Ar unwaith | 8ln | Oer | t≤0.2s | Dim Baglu |
e | yn y fan a'r lle | 12 Yn | Oer | t<0.2s | Baglu |
Pan fydd MCB yn destun gor-cerrynt parhaus, mae'r stribed bimetallig yn cynhesu ac yn plygu.Mae clicied electromecanyddol yn cael ei ryddhau pan fydd yr MCB yn gwyro'r stribed deu-fetelaidd.Pan fydd y defnyddiwr yn cysylltu'r clasp electromecanyddol hwn â'r mecanwaith gweithio, mae'n agor y cysylltiadau torrwr microcircuit.O ganlyniad, mae'n achosi i'r MCB ddiffodd a therfynu'r cerrynt sy'n llifo.Dylai'r defnyddiwr droi'r MCB ymlaen yn unigol i adfer y llif presennol.Mae'r ddyfais hon yn gwarchod rhag diffygion a achosir gan gerrynt gormodol, gorlwytho a chylchedau byr.